Plasterboard calculator

Sheets, screws, tape and compound for one or more surfaces, with openings subtracted and a stud count if you are building the wall too.

Surfaces to board
Openings to subtract
The board
2 for acoustic or fire upgrades
Framing, if you are building the wall too
0 to skip

This calculator runs in your browser and needs JavaScript switched on. The method is written out under How the figures are worked out.

How the figures are worked out

Net area. Surfaces added up as width × height × how many, less the openings you entered.

Sheets. Net area plus waste, divided by one sheet's area, rounded up, then multiplied by the number of layers.

Screws. 35 per sheet, rounded up to the nearest 50 so it matches how boxes are sold.

Joint tape. About 1.3 metres per square metre of board. That is a coverage figure from the trade tables, not geometry, and it assumes a normal mix of sheet sizes and joints.

Compound. About 0.5 kg per square metre of board over three passes — tape coat, fill coat, finish coat.

Studs. Wall run length divided by your stud centres, plus one for the end.

The screw, tape and compound figures are rules of thumb and the calculator says so. They are right enough to order from and wrong enough that you should buy a little over rather than exactly.

What to sort out before the board goes on

This is the last moment the inside of the wall is accessible, which makes it one of the most important points in a renovation. Everything on this list is cheap now and expensive the moment a sheet covers it.

Boards are heavy

A standard 1200 × 2400 mm sheet is a genuine two-person lift, more so on a ceiling, and moisture-resistant and fire-rated boards are heavier again. Count the stair turns and door widths before you order a pallet, and work out where it is going to be stacked — flat and supported, never leaning against a wall on edge, which bows the sheet permanently.

Ceilings need either props, a board lifter, or three people. There is no version of holding a sheet overhead with one hand and screwing with the other that ends well.

Common questions

How many screws per sheet?
Around 35 is the usual working figure for a 1200 by 2400 mm sheet at 600 mm centres — roughly every 200 to 300 mm along each stud. Check what your local standard specifies, because fire and acoustic ratings have their own fixing patterns and the spacing is part of the rating.
How much joint compound will I need?
About 0.5 kg per square metre of board across three passes, as a rule of thumb. It varies a lot with how good the boarding is: tight, well-aligned joints need very little, and a sheet that is 5 mm out needs a lot of filling to disappear.
Horizontal or vertical sheets?
Vertical is the usual choice for a stud wall, so every edge lands on a stud. Horizontal gives you fewer total joint metres and is standard on ceilings and in some commercial systems. Either way, stagger the joints between rows and never line up a board joint with the edge of a door opening.
Can I board over the old wall instead of stripping it?
Sometimes, and it has real costs: you lose room dimension, every socket and switch needs extending, skirtings and architraves need refitting, and you may be hiding a problem rather than fixing it. It is also the point at which you should know whether anything in that wall contains asbestos.

Updated 2026-11-21