Tell it the area and the thickness you are aiming for, and it works out the layers, the packs and the R-value you actually get rather than the one on the front of the pack.

Areas to insulate
The product
270 mm (about 11 in) is a common loft target
Mineral wool 0.044, glass wool 0.040, PIR board 0.022. It is on the pack.

This calculator runs in your browser and needs JavaScript switched on. The method is written out under How the figures are worked out.

How the figures are worked out

Area. Width × length × how many, added up over every area you entered, plus the waste allowance.

Layers. The thickness you want divided by the product thickness, rounded up. You cannot buy two-thirds of a layer, so the calculator tells you what you actually end up with rather than what you asked for.

Packs. Area with waste, multiplied by the layers, divided by the coverage printed on the pack, rounded up.

R-value. Actual thickness in metres divided by the conductivity λ. That is the whole formula: R = thickness ÷ λ. Both unit systems are shown because product data sheets mix them freely.

The number on the pack is not the number in the roof

The R-value here is the material on its own, laid properly, at full thickness, with nothing bridging it. Real roofs and walls are not that. The figure that building control cares about is a U-value for the whole build-up, which includes the timber, the plasterboard, the air gaps and anything that penetrates the layer. It is always worse than the material figure.

Treat this calculator as the answer to "how much do I buy" and a decent sanity check on thickness. For a compliance figure, the full build-up has to be calculated.

Three things that undo the work

Blocking the ventilation. Insulation pushed hard into the eaves stops the airflow that keeps a cold roof dry, and a cold roof without airflow grows mould in the sarking. Eaves vents or ventilation trays keep the gap open.

Burying downlights. Recessed lights run hot, and most of them have a clearance requirement that insulation laid over the top destroys. Fire-rated hoods exist for exactly this. Check before you cover anything.

Insulating a damp wall. Insulation does not dry anything out; it moves where the condensation happens, usually to somewhere you cannot see. Find out why a wall is wet before you cover it up.

Common questions

What R-value do I need?
It depends on your climate, the element and your local building rules, and those differ enough that no calculator can answer it. As a rough sense of scale, a modern cold-climate loft is usually somewhere around 6 to 7 m²K/W (R-34 to R-40) and a wall rather less. Ask your building authority what applies at your address before you order, because an upgrade that misses the requirement by a little is as non-compliant as one that misses it by a lot.
Why does the second layer go crossways?
Because the joists are the problem the first layer cannot solve. Insulation laid between joists leaves a continuous timber bridge every 400 or 600 mm, and timber conducts heat far better than wool does. The second layer laid at right angles over the top covers those bridges, which is where most of the remaining loss is.
Does compressing it matter?
A great deal. The performance comes from trapped still air, so squashing 270 mm of wool under loft boards down to 100 mm throws away most of what you paid for and leaves you with a floor you cannot easily undo. If you need storage up there, raise the boards on battens above the insulation.
What is the difference between the two R-values?
Only the units. The metric R is in m²K/W and the US R is in ft²·°F·h/BTU, and one is the other times 5.68. A pack sold as R-30 in the United States is about 5.3 m²K/W. They describe the same material, so compare like with like before you decide something is thin.